W10733412 Whirlpool Microwave High Voltage Transformer

Maintain the performance of your microwave with this high voltage transformer designed to meet the highest standards of durability and efficiency. Compatible with a range of brands, including Admiral, Amana, Jenn-Air, Kenmore, Kitchenaid, Magic Chef, Maytag, Norge, Roper, and Whirlpool, this transformer ensures seamless operation across various appliance models.
Crafted specifically for microwave parts, it delivers reliable power to keep your microwave running smoothly. Whether you are repairing an older unit or maintaining a newer one, this high voltage transformer is an essential component for optimal functionality. Trust in the quality and engineering of this Whirlpool part to restore your appliance's performance and longevity. Ideal for DIY enthusiasts and professionals alike, this replacement ensures you can prepare your meals efficiently once again.
Weight : 2.166700 lbs
Dimension : 7.165300 x 5.866100 x 7.165300
Maintain the performance of your microwave with this high voltage transformer designed to meet the highest standards of durability and efficiency. Compatible with a range of brands, including Admiral, Amana, Jenn-Air, Kenmore, Kitchenaid, Magic Chef, Maytag, Norge, Roper, and Whirlpool, this transformer ensures seamless operation across various appliance models.
Crafted specifically for microwave parts, it delivers reliable power to keep your microwave running smoothly. Whether you are repairing an older unit or maintaining a newer one, this high voltage transformer is an essential component for optimal functionality. Trust in the quality and engineering of this Whirlpool part to restore your appliance's performance and longevity. Ideal for DIY enthusiasts and professionals alike, this replacement ensures you can prepare your meals efficiently once again.
Weight : 2.166700 lbs
Dimension : 7.165300 x 5.866100 x 7.165300
Write Your Own Review
DIY Instructions for Replacing the Whirlpool W10733412 TRANSFORMER
1. Prepare to Replace the Transformer: Before you begin replacing the Whirlpool W10733412 TRANSFORMER, make sure that you have the right tools and safety equipment. You will need a flat-head screwdriver, wire cutters, Phillips-head screwdriver, and safety glasses or goggles.
2. Disconnect the Power Supply: Disconnect the power supply to the Whirlpool W10733412 TRANSFORMER. Unplug the power cord from the wall outlet or switch off the circuit breaker to ensure there is no electricity running through the transformer.
3. Remove the Cover: Using the flat-head screwdriver, carefully remove the cover from the transformer. Take note of any wiring configurations and the mounting screws for when you replace the transformer.
4. Cut the Wiring: Using the wire cutters, carefully cut the wires connected to the transformer. Make sure you don’t accidentally cut any other wiring by accident.
5. Unscrew the Old Unit: Use the Phillips-head screwdriver to unscrew the mounting screws from the transformer. Carefully pull it out from its housing.
6. Install the New Transformer: Line up the new transformer with the old one and carefully insert it into place. Screw the mounting screws back into place.
7. Connect the Wiring: Connect the wires to the terminals of the new transformer, making sure they are matched to their original configurations.
8. Replace the Cover: Put the cover back on the transformer, securing it with the flat-head screws.
9. Restore the Power Supply: Reconnect the power supply to the Whirlpool W10733412 TRANSFORMER and turn on the circuit breaker or plug the power cord into the wall outlet.
10. Test the Transformer: Run a test to make sure the transformer is working correctly.
Please keep in mind, these instructions are for general guidance and should always be used in conjunction with the manufacturer's manual, if available.
1. Prepare to Replace the Transformer: Before you begin replacing the Whirlpool W10733412 TRANSFORMER, make sure that you have the right tools and safety equipment. You will need a flat-head screwdriver, wire cutters, Phillips-head screwdriver, and safety glasses or goggles.
2. Disconnect the Power Supply: Disconnect the power supply to the Whirlpool W10733412 TRANSFORMER. Unplug the power cord from the wall outlet or switch off the circuit breaker to ensure there is no electricity running through the transformer.
3. Remove the Cover: Using the flat-head screwdriver, carefully remove the cover from the transformer. Take note of any wiring configurations and the mounting screws for when you replace the transformer.
4. Cut the Wiring: Using the wire cutters, carefully cut the wires connected to the transformer. Make sure you don’t accidentally cut any other wiring by accident.
5. Unscrew the Old Unit: Use the Phillips-head screwdriver to unscrew the mounting screws from the transformer. Carefully pull it out from its housing.
6. Install the New Transformer: Line up the new transformer with the old one and carefully insert it into place. Screw the mounting screws back into place.
7. Connect the Wiring: Connect the wires to the terminals of the new transformer, making sure they are matched to their original configurations.
8. Replace the Cover: Put the cover back on the transformer, securing it with the flat-head screws.
9. Restore the Power Supply: Reconnect the power supply to the Whirlpool W10733412 TRANSFORMER and turn on the circuit breaker or plug the power cord into the wall outlet.
10. Test the Transformer: Run a test to make sure the transformer is working correctly.
Please keep in mind, these instructions are for general guidance and should always be used in conjunction with the manufacturer's manual, if available.